> On Iau, 2003-06-12 at 16:56, Mike Dresser wrote:
> > If i have a hardware raid1 array of two 120 gig Maxtor DiamondMax 9 drives
> > on a 3ware 7000-2. Failure of one disk should not go all the way up to
> > the OS and cause the OS to report hard errors, and remount the drive as
> > read-only, right?
>
> Yes, but that won't help you if you lost both drives, which does happen
> now and again - overheating, bad PSU, using two drives from the same
> batch together and so on.
>
> The trace looks like you may have lost both drives.
>
> Alan
>
I'm heading out there today to take a look at the machine and see what
happened. I'm rather dissappointed in the 3ware utility, it alternately
claims both drives are ok(./tw_cli info c1 is different from ./tw_cli
info c1 u0)
I was relying on that too much, and ignored the possiblity of two drive
failure. Looks like both drives would have failed at exactly the same
time, which sounds like a power spike.
I just got a report that another Windows98 workstation is randomly
rebooting after an hour of uptime at the same facility, so I'm suspecting
hardware failure like you did.
I'll see what's up when I get there. Powermax will tell me what's up.
Luckily the damage is contained to the data drive, I will be able to copy
everything over to a new set of drives and not lose anything that's not
trivially replaceable.
Thank you Alan,
Mike
-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at http://vger.kernel.org/majordomo-info.html