On Mon, 2003-05-26 at 14:38, mikpe@csd.uu.se wrote:
> Disconnect writes:
> > Local APIC disabled by BIOS -- reenabling.
> > Found and enabled local APIC!
> >
> > And now /proc/cpuinfo and cpuid both show APIC support.
> >
> > Removed/replaced power, triggered lid-switch/battery-status/etc with no
> > issues. (The only thing that caused trouble was Fn-F10, the "eject cd"
> > button. Never tried it under Linux before, and the cd isn't in it at
> > the moment anyway, so I'm betting thats unrelated. But it did cause a
> > lockup that even sysrq couldn't recover.)
>
> Nice.

> > Not 100% clear on what the APIC does, but I'm not sure its doing it ;)
> >
> > PCI: Using ACPI for IRQ routing <-- shouldn't this be missing if the
> > APIC is in use?
>
> Nope. local APIC != I/O APIC. Disable ACPI, or enable IO_APIC (and hope it's there).

I'm betting it doesn't have an IO-APIC (its a laptop, no SMP, etc) ..
any way to tell if the APIC is working/enabled? (For that matter, all
google could tell me about was the IO-APIC, which is handy to know but
not particularly helpful here.)

> > (Full dmesg attached, for those who are curious - the unknown-scancode
> > is for the various laptop buttons - bright/dim, vol, media, battery,
> > etc. Except for the volume buttons the only ones that work are the ones
> > that directly hit the hardware, ala bright/dim.)
> >
> > Also, for others with an I8500 who might read the dmesg log, don't get
>
> dmidecode data would be nice, for the whitelist rules.

Attached (I pulled out the service tag and express service code, both of
which are local to the individual device.)

Also, not sure what (if anything) would be different with the A01 bios;
their changelog seems to focus mostly on fixing a sound bug (which,
unfortunately, I didn't have until -after- the fix... sigh.)

Their changelog is online ( support.dell.com 'small business' ->
'Inspiron 8500' -> 'FlashBIOS updates') but there's not much to it.

-- 
Disconnect <lkml@sigkill.net>

--=_courier-23563-1053978671-0001-2 Content-Type: text/plain; name="dmidecode.txt"; charset=iso-8859-1 Content-Transfer-Encoding: 7bit Content-Disposition: inline; filename=dmidecode.txt

# dmidecode 1.8 SYSID present. Revision: 0 1 structure. SYSID table at 0x000F8CD1. SMBIOS 2.3 present. DMI 2.3 present. 59 structures occupying 2398 bytes. DMI table at 0x000F8D10. Handle 0xDA00 DMI type 218, 101 bytes. b2 00 0d 1f 0f 17 40 7d 00 00 00 00 00 7e 00 02 ......@}.....~.. 00 00 00 40 00 04 00 01 00 41 00 04 00 00 00 90 ...@.....A...... 00 05 00 00 00 91 00 05 00 01 00 92 00 05 00 02 ................ 00 00 80 00 80 01 00 00 a0 00 a0 01 00 05 80 05 ................ 80 01 00 01 f0 01 f0 00 00 02 f0 02 f0 00 00 03 ................ f0 03 f0 00 00 04 f0 04 f0 00 00 ff ff 00 00 00 ................ 00 . Handle 0x0000 DMI type 0, 20 bytes. BIOS Information Block Vendor: Dell Computer Corporation Version: A02 Release: 04/29/2003 BIOS base: 0xF0000 ROM size: 512K Capabilities: Flags: 0x001700007D019F90 Handle 0x0100 DMI type 1, 25 bytes. System Information Block Vendor: Dell Computer Corporation Product: Inspiron 8500 Version: Serial Number: [removed svc tag] Handle 0x0200 DMI type 2, 9 bytes. Board Information Block Vendor: Dell Computer Corporation Product: 00U838 Version: Serial Number: .[removed svc tag].[removed express svc code]. Handle 0x0300 DMI type 3, 13 bytes. Chassis Information Block Vendor: Dell Computer Corporation Chassis Type: Portable Version: Serial Number: [removed svc tag] Asset Tag: Handle 0x0301 DMI type 126, 13 bytes. Inactive Handle 0x0400 DMI type 4, 32 bytes. Processor Socket Designation: Microprocessor Processor Type: Central Processor Processor Family: Processor Manufacturer: Intel Processor Version: Handle 0x0700 DMI type 7, 19 bytes. Cache Socket: L1 Internal Cache: write-back L1 Cache Size: 8K L1 Cache Maximum: 8K L1 Cache Type: Unknown Handle 0x0701 DMI type 7, 19 bytes. Cache Socket: L2 Internal Cache: L2 Cache Size: 512K L2 Cache Maximum: 512K L2 Cache Type: Pipeline burst Handle 0x0800 DMI type 8, 9 bytes. Port Connector Internal Designator: PARALLEL Internal Connector Type: None External Designator: External Connector Type: DB-25 pin female Port Type: Parallel Port PS/2 Handle 0x0801 DMI type 8, 9 bytes. Port Connector Internal Designator: SERIAL1 Internal Connector Type: None External Designator: External Connector Type: DB-9 pin male Port Type: Serial Port 16550A Compatible Handle 0x0803 DMI type 126, 9 bytes. Inactive Handle 0x0804 DMI type 8, 9 bytes. Port Connector Internal Designator: USB Internal Connector Type: None External Designator: External Connector Type: Access Bus (USB) Port Type: USB Handle 0x0805 DMI type 126, 9 bytes. Inactive Handle 0x0806 DMI type 8, 9 bytes. Port Connector Internal Designator: MONITOR Internal Connector Type: None External Designator: External Connector Type: DB-15 pin female Port Type: Video Port Handle 0x0808 DMI type 126, 9 bytes. Inactive Handle 0x0809 DMI type 8, 9 bytes. Port Connector Internal Designator: IrDA Internal Connector Type: None External Designator: External Connector Type: Infrared Port Type: Other Handle 0x080A DMI type 126, 9 bytes. Inactive Handle 0x080B DMI type 8, 9 bytes. Port Connector Internal Designator: FireWire Internal Connector Type: None External Designator: External Connector Type: 1394 Port Type: FireWire (IEEE P1394) Handle 0x080C DMI type 8, 9 bytes. Port Connector Internal Designator: Modem Internal Connector Type: None External Designator: External Connector Type: RJ-11 Port Type: Modem Port Handle 0x080D DMI type 8, 9 bytes. Port Connector Internal Designator: Ethernet Internal Connector Type: None External Designator: External Connector Type: RJ-45 Port Type: Network Port Handle 0x0900 DMI type 9, 13 bytes. Card Slot Slot: PCMCIA 0 Type: 32bit PCMCIA Status: Available. Slot Features: 5v 3.3v PCCard16 CardBus Zoom-Video ModemRingResume Handle 0x0902 DMI type 126, 13 bytes. Inactive Handle 0x0904 DMI type 9, 13 bytes. Card Slot Slot: MiniPCI Type: 32bit Status: Available. Slot Features: 5v 3.3v Handle 0x0A00 DMI type 10, 6 bytes. On Board Devices Information Description: ATI Radeon 9000 : Enabled Type: Video Handle 0x0A01 DMI type 10, 6 bytes. On Board Devices Information Description: Sigmatel 9750 : Enabled Type: Sound Handle 0x0B00 DMI type 11, 5 bytes. OEM Data Dell System 5[0015] Handle 0x0D00 DMI type 13, 22 bytes. BIOS Language Information Installable Languages: 1 en|US|iso8859-1 Currently Installed Language: en|US|iso8859-1 Handle 0x1000 DMI type 16, 15 bytes. Physical Memory Array Location: System board or motherboard Use: System memory Error Correction Type: None Maximum Capacity: 1048576 kB Error Information Handle: Not Provided Number of Devices: 2 Handle 0x1100 DMI type 17, 27 bytes. Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 64 bits Data Width: 64 bits Size: 256 Mbyte Form Factor: DIMM Locator: DIMM_A Bank Locator: Type: DDR Type Detail: Synchronous Speed: 266 MHz (3.8 ns) Manufacturer: Serial Number: Asset Tag: Part Number: Handle 0x1101 DMI type 17, 27 bytes. Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 64 bits Data Width: 64 bits Size: 256 Mbyte Form Factor: DIMM Locator: DIMM_B Bank Locator: Type: DDR Type Detail: Synchronous Speed: 266 MHz (3.8 ns) Manufacturer: Serial Number: Asset Tag: Part Number: Handle 0x1300 DMI type 19, 15 bytes. Memory Array Mapped Address Handle 0x1301 DMI type 19, 15 bytes. Memory Array Mapped Address Handle 0x1400 DMI type 20, 19 bytes. Memory Device Mapped Address Handle 0x1401 DMI type 20, 19 bytes. Memory Device Mapped Address Handle 0x1402 DMI type 20, 19 bytes. Memory Device Mapped Address Handle 0x1500 DMI type 21, 7 bytes. Built-In Pointing Device Handle 0x1600 DMI type 22, 26 bytes. Portable Battery Location: Sys. Battery Bay Manufacturer: Sony Corp. Manufacture Date: Serial Number: Name: DELL 0005P14 Handle 0x1601 DMI type 126, 26 bytes. Inactive Handle 0x1602 DMI type 126, 26 bytes. Inactive Handle 0x1B00 DMI type 27, 12 bytes. Cooling Device Device Type: Fan Device Status: OK Handle 0x1C00 DMI type 28, 20 bytes. Temperature Sensor Description: CPU Internal Temperature Device Location: Processor Device Status: OK Maximum Value: 127.0 Minimum Value: 0.0 Resolution: 100.0 Tolerance: 0.5 Accuracy: Unknown Handle 0x1F00 DMI type 31, 28 bytes. Boot Integrity Services Entry Point Handle 0x2000 DMI type 32, 11 bytes. System Boot Information Handle 0xD000 DMI type 208, 10 bytes. 01 04 fe 00 3e 01 ....>. Handle 0xD100 DMI type 209, 12 bytes. 00 00 00 03 04 07 80 05 ........ Handle 0xD200 DMI type 210, 12 bytes. f8 03 04 03 06 80 04 05 ........ Handle 0xD300 DMI type 211, 13 bytes. 01 03 02 01 00 00 00 00 02 ......... Handle 0xD800 DMI type 216, 9 bytes. 01 03 01 f0 03 ..... Handle 0xD900 DMI type 217, 8 bytes. 01 02 01 03 .... Handle 0xDB00 DMI type 219, 8 bytes. 03 01 02 03 .... Handle 0xDB80 DMI type 126, 8 bytes. Inactive Handle 0xDB81 DMI type 126, 8 bytes. Inactive Handle 0xDC00 DMI type 220, 22 bytes. 01 f0 00 00 02 f0 00 00 00 00 03 f0 04 f0 00 00 ................ 00 00 .. Handle 0xDD00 DMI type 221, 19 bytes. 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ............... Handle 0xD400 DMI type 212, 227 bytes. 70 00 71 00 00 10 2d 2e 5c 00 78 bf 40 5d 00 78 p.q...-.\.x.@].x bf 00 5e 00 23 fe 01 5f 00 23 fe 00 65 00 21 f7 ..^.#.._.#..e.!. 00 66 00 21 f7 08 f1 00 21 fc 00 f2 00 21 fc 01 .f.!....!....!.. f3 00 21 fc 02 0f 00 26 f8 00 11 00 26 f8 01 05 ..!....&....&... 00 26 f8 02 12 00 26 f8 03 06 00 26 f8 04 31 00 .&....&....&..1. 26 8f 00 32 00 26 8f 10 33 00 26 8f 20 34 00 26 &..2.&..3.&. 4.& 8f 30 35 00 26 8f 40 07 00 25 f8 00 0b 00 25 f8 .05.&.@..%....%. 01 0c 00 25 f8 02 0d 00 25 f8 04 28 00 23 f3 00 ...%....%..(.#.. 29 00 23 f3 04 2a 00 23 f3 08 2b 00 58 00 00 2c ).#..*.#..+.X.., 00 59 00 00 e7 00 1d f3 04 e6 00 1d f3 00 0e 01 .Y.............. 23 fd 00 0f 01 23 fd 02 9b 00 23 ef 10 9c 00 23 #....#....#....# ef 00 87 00 11 fd 02 88 00 11 fd 00 e8 00 23 df ..............#. 00 e9 00 23 df 20 12 01 34 fb 04 13 01 34 fb 00 ...#. ..4....4.. 08 00 1d df 00 03 00 1d df 00 ff ff 00 00 00 ............... Handle 0xD401 DMI type 212, 132 bytes. 70 00 71 00 03 40 49 4a 42 00 48 7f 80 43 00 48 p.q..@IJB.H..C.H 7f 00 55 00 47 bf 00 6d 00 47 bf 40 0c 01 46 fb ..U.G..m.G.@..F. 04 0d 01 46 fb 00 14 01 46 e7 00 15 01 46 e7 08 ...F....F....F.. 16 01 46 e7 10 0a 01 48 ef 10 0b 01 48 ef 00 2d ..F....H....H..- 00 48 df 20 2e 00 48 df 00 a8 00 48 fc 01 a9 00 .H. ..H....H.... 48 fc 00 b2 00 48 fc 02 11 01 48 bf 00 10 01 48 H....H....H....H bf 40 f0 00 46 3f 20 ed 00 46 3f 00 ea 00 67 f3 .@..F? ..F?...g. 00 eb 00 67 f3 04 ec 00 67 f3 08 ff ff 00 00 00 ...g....g....... Handle 0xDE00 DMI type 222, 13 bytes. 01 02 ff ff 00 00 00 00 00 ......... Handle 0x7F00 DMI type 127, 4 bytes. End-of-Table PCI Interrupt Routing 1.0 present. Table Size: 176 bytes Router ID: 00:1f.0 Exclusive IRQs: None Compatible Router: 8086:1234 ACPI 1.0 present. OEM ID: DELL RSD table at 0x1FFF0000. PNP 1.0 present. Event Notification: Polling Event Notification Flag Address: 0x000004B4 Real Mode Code Address: F000:E2F1 Real Mode Data Address: 0040:0000 Protected Mode Code Address: 0x000FE2F4 Protected Mode Data Address: 0x00000040 BIOS32 Service Directory present. Calling Interface Address: 0x000FFE90

--=_courier-23563-1053978671-0001-2--