There is no bug, except in your BIOS maybe.
Cheers,
On Sat, 5 Apr 2003, Stephan van Hienen wrote:
> On Sat, 5 Apr 2003, Mark Hahn wrote:
>
> > > > > I don't think it is doing U100 :
> > > >
> > > > why? 25 MB/s is exactly what you should expect from a disk
> > > > which has around 15 GB/platter density. the transfer mode
> > > > doesn't matter, as long as it's 10-20% faster than the transfer
> > > > rate of the disk's outer tracks.
> > >
> > > because it is the same disk (WD1800BB (180GB)) only difference is the
> > > controller...
> >
> > is the 80-pin cable validly configured and properly detected?
> > or did you cover this already?
>
> all disks and cables are the same
> (i have 15 of these disks in this server)
> only difference are the controllers
>
> and since the kernel is giving me incorrect info at boottime
> (ICH3 (instead of what is really there (ICH4))
> i really think this is an kernel problem
> -
> To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
> the body of a message to majordomo@vger.kernel.org
> More majordomo info at http://vger.kernel.org/majordomo-info.html
> Please read the FAQ at http://www.tux.org/lkml/
>
Andre Hedrick
LAD Storage Consulting Group
-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at http://vger.kernel.org/majordomo-info.html