md and raid is the same and not split yet as Niel proposed.
> during boot with initrd. In the reality I have some servers with more that
> 200 days of uptime, and I have to change external disks sometime. I do
> usually have two external boxes, and something like 8/20 disks (two scsi
> controllers), and different raid on different disks. You see, it is not
> that easy.
Currently, if you have raid compiled as modules the autodetection does not
work, and is disabled. The issue here is enabling autodetection from the
modules, wheather that be at boot time or not. If you use raid modules you
won't get the autodetection and the features that come with that.
When adding a new disk, you would have to add it to an array manually with
the raidtools2 anyway, so this is unchanged.
Mike
-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/