raid reboot notifier priority causes reboot oops
Andreas Steinmetz (ast@domdv.de)
Tue, 11 Sep 2001 01:24:00 +0200 (CEST)
Hi,
just sorted this out:
the raid code uses a reboot notifier of 0 which badly interferes with scsi
drivers using the same reboot notifier priority. This may (and does) cause scsi
to shut down prior to raid. A sensible value >0 is required for the raid reboot
notifier priority to prevent this.
Andreas Steinmetz
D.O.M. Datenverarbeitung GmbH
-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org